Clamp-on Ultrasonic Flowmeter

ULTRASONIC FLOW MEASUREMENT

What Is a Clamp-On Ultrasonic Flow Meter?

A clamp-on ultrasonic flow meter is a non-invasive flow measurement solution that measures liquid flow without cutting the pipe by mounting the sensor on the outer surface of the pipe.

Lorric FU-ES EchoSense can be quickly installed on existing piping systems thanks to its compact integrated display and sensor design, QuickClamp mounting system, special contact pad that requires no ultrasonic coupling gel, and 4–20 mA, RS-485 Modbus and pulse outputs.

Installation in 3 Steps, in Approximately 3 Minutes

Using the QuickClamp design, the sensor can be quickly mounted on the outer surface of the pipe without cutting the pipe or modifying the process. Thanks to the special ultrasonic contact pad, no ultrasonic coupling gel is required during installation.

3 Steps ≈ 3 Minutes No Pipe Cutting No Gel Required
01 · QUICKCLAMP
Lorric FU-ES QuickClamp installation step 1
02 · QUICKCLAMP
Lorric FU-ES QuickClamp installation step 2
03 · QUICKCLAMP
Lorric FU-ES QuickClamp installation step 3
Outputs available on all models
4–20 mA RS-485 Modbus RTU Pulse
MODEL
IMAGE
FLOW RANGE
NOMINAL PIPE SIZE
COMPATIBLE PIPE OUTER DIAMETER
MODEL
FU-ES015
Lorric FU-ES015 Clamp-on Ultrasonic Flow Meter
FLOW RANGE
1.5–96
L/min
NOMINAL PIPE SIZE
DN15
1/2"
COMPATIBLE PIPE OUTER DIAMETER
Pipe outer diameter
20–22 mm
0.79–0.87 in
MODEL
FU-ES020
Lorric FU-ES020 Clamp-on Ultrasonic Flow Meter
FLOW RANGE
2–160
L/min
NOMINAL PIPE SIZE
DN20
3/4"
COMPATIBLE PIPE OUTER DIAMETER
Pipe outer diameter
25–27.2 mm
0.98–1.07 in
MODEL
FU-ES025
Lorric FU-ES025 Clamp-on Ultrasonic Flow Meter
FLOW RANGE
3–240
L/min
NOMINAL PIPE SIZE
DN25
1"
COMPATIBLE PIPE OUTER DIAMETER
Pipe outer diameter
32–34 mm
1.26–1.34 in
MODEL
FU-ES032
Lorric FU-ES032 Clamp-on Ultrasonic Flow Meter
FLOW RANGE
5–376
L/min
NOMINAL PIPE SIZE
DN32
1-1/4"
COMPATIBLE PIPE OUTER DIAMETER
Pipe outer diameter
38–42.16 mm
1.50–1.66 in
MODEL
FU-ES040
Lorric FU-ES040 Clamp-on Ultrasonic Flow Meter
FLOW RANGE
8–616
L/min
NOMINAL PIPE SIZE
DN40
1-1/2"
COMPATIBLE PIPE OUTER DIAMETER
Pipe outer diameter
48–50 mm
1.89–1.97 in
MODEL
FU-ES050
Lorric FU-ES050 Clamp-on Ultrasonic Flow Meter
FLOW RANGE
13–1056
L/min
NOMINAL PIPE SIZE
DN50
2"
COMPATIBLE PIPE OUTER DIAMETER
Pipe outer diameter
60–63 mm
2.36–2.48 in
MODEL
FU-ES065
Lorric FU-ES065 Clamp-on Ultrasonic Flow Meter
FLOW RANGE
22–1336
L/min
NOMINAL PIPE SIZE
DN65
2-1/2"
COMPATIBLE PIPE OUTER DIAMETER
Pipe outer diameter
73–76.3 mm
2.87–3.00 in
MODEL
FU-ES075
Lorric FU-ES075 Clamp-on Ultrasonic Flow Meter
FLOW RANGE
30–1496
L/min
NOMINAL PIPE SIZE
DN75
3"
COMPATIBLE PIPE OUTER DIAMETER
Pipe outer diameter
88.9–90 mm
3.50–3.54 in
Flow measurement ranges are specified by LORRIC based on 20 °C water and PVC pipe as reference conditions. When selecting a model, the actual pipe outer diameter must be checked together with the nominal pipe size. The FU-ES sensor is mounted externally on the pipe using a clamp-on installation method.
LORRIC FU-ES ECHOSENSE
Technical Specifications
 
MEASUREMENT & PROCESS
Installation Method
External Pipe Mounting · Clamp-On No Pipe Cutting No Ultrasonic Gel Required
Thanks to the QuickClamp mounting system and special ultrasonic contact pad, the sensor can be quickly installed on the outer surface of the pipe.
Compatible Pipe Materials
Metal Pipes UPVC PPH PVDF
Especially for copper pipes, the actual pipe outer diameter should be checked instead of relying solely on the nominal pipe size.
Compatible Fluids
Water, oil, chemicals and various liquids
The fluid to be measured must be free from solid particles / impurities and air bubbles.
Fluid Temperature
0…+85 °C
The pipe surface must be free from ice formation.
Velocity Measurement Range
Recommended: ±0.3…6.0 m/s Measurable: ±0.1…10 m/s
Flow Measurement Range
Varies depending on the selected FU-ES model and pipe diameter. Current model-specific measurement ranges are listed in the FU-ES Ultrasonic Flow Meter Models table above.
LORRIC calculates the flow ranges using water at 20 °C and PVC pipe as reference conditions.
Measurement Accuracy
±3.0% RD · 10–100% F.S. ±0.3% F.S. · 0–10% F.S.
Accuracy values were obtained at 25 °C in a controlled laboratory environment with defined pipe and fluid conditions after zero calibration of the device. Measurement accuracy may vary under actual field conditions.
Units
meter, m³, liter, s, min, hour, day, feet, feet³, UK gallon, US gallon
ELECTRICAL & COMMUNICATION
Power Supply
12…36 VDC
Current Consumption
<200 mA @ 12 VDC
Specified for startup and steady-state operation; communication current is not included.
Output Signals
4–20 mA RS-485 · Modbus RTU 2-Wire Optocoupler Switch / Pulse
Cable & Connector
M12 · 8-pin connector
A 2 m connection cable is included in the package.
Electrical Protection
Reverse Polarity Protection Surge Protection
DEVICE & PROTECTION
Display
Dual display
5-digit LED · 3-line × 16-character LCD · 3-color backlight
Display Update Time
0.5 s / 1 s
Display Resolution
Maximum 0.0001
Operating Ambient Temperature
−10…+60 °C · Freezing must not occur.
Relative Humidity
35…85% RH · Non-Condensing
Protection Rating
IP66
Improperly loosening the screws around the display to change its orientation may affect the IP66 protection rating.
Certifications
FCC CE RoHS UL · Special Order
The UL-certified version must be specified separately when ordering; it is specially manufactured with a different model code and straight cable connector.

 

 

LORRIC FU-ES ECHOSENSE
Interactive User Manual
 
You can access the latest operating instructions, commissioning information, parameter settings, mechanical installation and electrical connection details for the LORRIC FU-ES EchoSense Clamp-On Ultrasonic Flow Meter through the interactive user manual below.
The manual content is updated online by LORRIC. If you need to view the content in a separate window, you can use the link below.
LORRIC FU-ES ECHOSENSE
Installation Details
 
You can review the correct installation location for the FU-ES EchoSense Clamp-On Ultrasonic Flow Meter, required straight pipe lengths, distance from flow-disturbing equipment such as pumps and valves, pipe orientation, sensor mounting position, and QuickClamp mechanical installation details in the LORRIC interactive installation guide below.
Mechanical installation information is updated online by LORRIC. If you need to view the content in a separate window, you can use the link below.
LORRIC FU-ES ECHOSENSE
Electrical Connection
 
You can review the power supply, M12 8-pin connector wiring, 4–20 mA analog output, OCT pulse output, and RS-485 Modbus communication connections for the FU-ES EchoSense Clamp-On Ultrasonic Flow Meter in the LORRIC interactive wiring guide below.
Electrical connection information is updated online by LORRIC. If you need to view the content in a separate window, you can use the link below.
Demo software downloads will be activated by filling out the form.
Now you can download the following software suitable for you. After clicking the button, the download link of the software will be sent to your e-mail address.
WhatsApp
×
Demo of this product is available.

You can download the free demo to try this product. To access the download form click.